4016 Power Wiring Unit 2

The power wiring is buried under the transformer mount.  It includes:

  1. Line filter
  2. 3 way terminal block
  3. Power switch
  4. Fuse
  5. Power Cord

Generally, the mains wiring was in good condition.  It all had to be removed for painting, though.

The power cord was unsightly, and I replaced it with a new-ish power cord that included a modern moulded mains plug.

I added heatshrink over the high voltage transformer leads just in case the insulation had become brittle.

The DC wiring had a few nibbles that were covered with heatshrink.  I missed one and applied liquid insulation tape to make do.

The capacitor was reformed using a bench supply.

Rust on the transformer was treated with deoxit and wire brush.

Voltages were checked initially at 24V and then at 240V.