The power wiring was a little different to the other unit and also different from the schematic.  In particular, the switch and fuse were after the filter.  I changed it to be the same as the other unit.

Other than that, the process was much the same as for Unit 2.

The capacitor was reformed on a DC supply and the transformer voltages were checked before connecting the processor board.

All earth points were stripped of paint and checked.